• Industrial Brackish Water RO Treatment Systems Manufacturers, Industrial Brackish Water RO Treatment Systems Factory, China Industrial Brackish Water RO Treatment Systems
  • Industrial Brackish Water RO Treatment Systems Manufacturers, Industrial Brackish Water RO Treatment Systems Factory, China Industrial Brackish Water RO Treatment Systems
  • Industrial Brackish Water RO Treatment Systems Manufacturers, Industrial Brackish Water RO Treatment Systems Factory, China Industrial Brackish Water RO Treatment Systems
  • video

Industrial Brackish Water RO Treatment Systems

Industrial Brackish Water RO Treatment Systems

Industrial Brackish Water RO Treatment Systems is used to remove salt and purify water. This system consists of booster pump, FRP/Carbon Steel pretreatment tanks (sand filter, activated carbon filter), SS304 cartridge filter housing, chemical dosing systems, high pressure pump, FRP membrane pressure vessel, 4040 or 8040 membranes, control panel and touch screen control.
Material and parts brand can be changes as regards to raw water quality and customer demand.
From touch screen panel, you can see all system flow diagram and automatic or manual control the system.
Membranes do not allow small particles, virus, bacteria to pass as a result your water becomes very clean and safe.

Industrial Brackish Water RO Treatment Systems

INDUSTRIAL BRACKISH WATER RO TREATMENT SYSTEMS

Brackish Water Desalination Plant

Industrial Brackish Water Desalination Plant Capacity range between 48m3/hour to 7500m3/day. If you need smaller than this capacity please see our commercial Brackish Water RO Plant.


If the water TDS is more than 1000ppm, we call this one as brackish water. Different source of science books defines brackish water TDS as different. But if water is not tap water and seawater, and TDS between 100 to 12000ppm, it can be called as brackish water.


All Brackish Water Treatment Plants are started from booster pump, it feeds raw water to pretreatment tanks. Depends on capacity pretreatment tank size and numbers can be changed. Because of High TDS (Total Dissolved Solid) we usually use FRP and Carbon Steel Tanks but we can check your raw water source analysis and we can suggest alternative material. If salt content and TDS high, because of the corrosion, we are using FRP or Carbon Steel material for pretreatment tanks. 


Pretreatment consists of Sand Media Filter Tank, Activated Carbon Filter Media Tank and Softener Tank which has ion exchange resin inside, they are very important for Brackish Water Desalination Plant.

Brackish Water RO Plant

Pretreatment is used to remove large number of suspended solids, iron, turbidity, unwanted color, unpleasant taste, chlorine, sediment, organic contaminants, odors. In pretreatment we can control the flow by manual or automatic for Brackish Water RO Plant.


After pretreatment water goes to cartridge filter housing, we call it as security filter, most of application we are using stainless steel 304 or 316 material, but if water is very salty like brackish or seawater, we can use carbon steel or FRP or PVC Plastic Cartridge Filter Housing or Bag Filter Housing. There is 1µm or 5 µm PP filter in cartridge filter housing Brackish Water RO Plant.


After cartridge filter housing, water goes to membrane pressure vessel with High Pressure Pump, you have brand option for High Pressure Pump and it allows you to adjust your budget. Membrane housing shell inside depends on capacity we have 4040 or 8040 Membranes. Most of our Brackish Water Treatment Plant project we are using DOW Filmtec, Toray , Vontron, Hydranautics, LG brand ro membranes.


Membranes, in industrial Brackish Water Desalination Plant, are most important part. They block if particle size bigger than 0.001µm and molecular weight up to 150-250Dalton. It consists of impurities, particles, sugars, proteins, bacteria, dyes, organic and inorganic solids.


Also Brackish Water Treatment Plant system can have chemical dosing at pretreatment or post treatment, like antiscaling (antiscalant), antifouling,  pH adjustment, Sterilization & Disinfection chemicals.

Brackish Water Treatment Plant

In Chunke when we check customer water analysis report, sometimes because of scaling and fouling problems, we can use CIP (Clean In Place) System, it wash membrane in membrane housing and make membrane life longer.

 

Parts for Brackish Water RO Plant

Brackish Water Desalination Plant

 

Electrical Power of industrial Brackish Water RO Plant

For industrial Brackish Water Treatment Plant needs 220-380V/50Hz/60Hz. For bigger capacity, because of high pressure pump, it needs 380V 50/60Hz. As regards to your Brackish Water RO Plant machine design, we will check your electrical supply and decide fix power to you.



Membrane Sizes and Quantity for BWRO Water Treatment Plant

Model Number

Permeate Flow Rate

 Membranes

Liter/Hour

Size

Quantity

CK-RO-2000L

2000

4040

8-10

CK-RO-3000L

3000

8040

4

CK-RO-4000L

4000

8040

4-6

CK-RO-5000L

5000

8040

5-6

CK-RO-6000L

6000

8040

6-8

CK-RO-8000L

8000

8040

8-10

CK-RO-10000L

10000

8040

12

CK-RO-15000L

15000

8040

16-18

CK-RO-20000L

20000

8040

24-25

CK-RO-30000L

30000

8040

35-40

CK-RO-45000L

45000

8040

50-60

CK-RO-100000L

100000

8040

110-120

CK-RO-200000L

200000

8040

220-240


Before Buying Industrial Brackish Water Desalination Plant,you should know:

1. Pure Water Production Capacity (L/day, L/Hour, GPD).

2. Feed Water TDS and Raw Water Analysis Report (prevent fouling and scaling problem)

3. Iron and Manganese must be removed before raw water enter to membrane of Brackish Water Desalination Plant

4. TSS (Total Suspended Solid) must remove before industrial Brackish Water Treatment Plant‘s membrane.

5. SDI (Silt Density Index) must be less than 3

6. Must be sure your water source does not have oil and grease

7. Chlorine must be removed before industrial Brackish Water RO Plant

8. Available electrical power voltage and phase

9. Layout of place for industrial Brackish Water RO Plant

 

Features of Industrial Brackish Water Desalination Plant

Standard Futers

Available Options

Programmable PLC Control

Automatic Flush 

Motor Starter 

Ozone Generator

Raw Water Feeding/Booster Pump

UV Sterilizer

Stainless Steel Cartridge Filter Housing

Chemical Dosing

FRP Membrane Housing

pH control monitor

Mitsubishi Processor Control

ORP Control monitor

Low Pressure Switch

Remote Control

High Pressure Switch

Pretreatment System

Liquid filled pressure gauge

Post Deionization Unit

Stainless Steel 304 Frame

CIP Membrane cleaning system

Permeate Conductivity Monitor

Touch Screen Control

Raw Water Conductivity Monitor

Tank Level Switch

Membranes

Customer Logo

Control Valves


Stainless Steel/UPVC Piping



Operation Specification for Industrial Brackish Water RO Plant

Feed Water TDS > 1000ppm

Hardness over 18ppm needs antiscalant dosing

Turbidity must be removed

Max. Feed Water Temp: 42°C

Operate at higher TDS results lower recovery

H2S must be removed

pH tolerance: 3-11

Max. iron content: 0.05ppm


Feed Water Pressure: 1.5 to 6 bar

Max. Silica tolerance: 60ppm



FAQ
Are you manufacturer or trading company ?
Yes, we are manufacturer. Our factory is in Guangzhou Baiyun and it is very near to Baiyun airport. When you come to China, you can visit our factory....more
Get the latest price? We'll respond as soon as possible(within 12 hours)

Privacy policy

close left right