• Industrial Seawater RO Desalination Systems Manufacturers, Industrial Seawater RO Desalination Systems Factory, China Industrial Seawater RO Desalination Systems
  • Industrial Seawater RO Desalination Systems Manufacturers, Industrial Seawater RO Desalination Systems Factory, China Industrial Seawater RO Desalination Systems
  • Industrial Seawater RO Desalination Systems Manufacturers, Industrial Seawater RO Desalination Systems Factory, China Industrial Seawater RO Desalination Systems
  • video

Industrial Seawater RO Desalination Systems

Industrial Seawater RO Desalination Systems

Industrial RO Seawater Desalination Plant is used to remove salt and purify water. This system consists of booster pump, FRP/Carbon Steel pretreatment tanks (sand filter, activated carbon filter), cartridge filter housing, chemical dosing systems, high pressure pump, FRP membrane pressure vessel, 4040 or 8040 membranes, control panel and touch screen control.
Material and parts brand can be changes as regards to raw water quality and customer demand.
From touch screen panel, you can see all system flow diagram and automatic or manual control the system.
Membranes do not allow small particles, virus, bacteria to pass as a result your water becomes very clean and safe.

Industrial Seawater RO Desalination Systems

INDUSTRIAL SEAWATER RO TREATMENT SYSTEMS

RO Seawater Desalination Plant

Industrial RO Seawater Desalination Plant Capacity range between 2m3/hour to 2500m3/day. If you need smaller than this capacity please see our commercial RO Desalination Machine.


All RO Seawater Desalination Plants are started from booster pump, it feeds raw water to pretreatment tanks. Depends on capacity pretreatment tank size and numbers can be changed. Because of High TDS (total dissolve solid) and salt water’s corrosion, we are using FRP or Carbon Steel material for pretreatment tanks. Pretreatment consists of Sand Media Filter Tank, Activated Carbon Filter Media Tank and Softener Tank which has ion exchange resin inside, they are very important for Industrial RO Desalination Machine.


Reverse Osmosis Seawater Purification


Pretreatment is used to remove large number of suspended solids, iron, turbidity, unwanted color, unpleasant taste, chlorine, sediment, organic contaminants, odors. In pretreatment we can control the follow manual or automatic for Reverse Osmosis Seawater Purification Plant.


After pretreatment water goes to cartridge filter housing, we call it as security filter, most of application we are using FRP or PVC Plastic material for cartridge filter housing or Bag Filter Housing. There is 1µm or 5 µm PP filter in cartridge filter housing for Reverse Osmosis Seawater Purification System.


After cartridge filter housing, water goes to membrane pressure vessel with High Pressure Pump, you have brand option for High Pressure Pump (Grundfos, Danfoss, CNP or Chunke) and it allows you to adjust your budget. Membrane housing shell inside depends on capacity we have 4040 or 8040 Membranes. Most of our project we are using DOW Filmtec, Toray , Vontron, Hydranautics, LG brand SW RO Membranes.


Industrial RO Desalination Machine


Membranes, in industrial Brackish Water Desalination Plant, are most important part. They block if parts size bigger than 0.001µm and molecular weight up to 150-250Dalton. It consists of impurities, particles, sugars, proteins, bacteria, dyes, organic and inorganic solids.


Also RO Seawater Desalination Plant can have chemical dosing at pretreatment or post treatment, like antiscaling (antiscalant) , antifouling,  pH adjustment, Sterilization & Disinfection chemicals.


In Chunke when we check customer water analysis report, sometimes because of scaling and fouling problems, we can use CIP (Clean In Place) System, it wash membrane in membrane housing and make membrane life longer.

 

Parts for Industrial Seawater RO Desalination Machine

RO Seawater Desalination Plant

 

Electrical Power of Industrial RO Desalination Machine

For industrial Reverse Osmosis Seawater Purification System needs 380V/50Hz/60Hz or . For bigger capacity, because of high pressure pump, it needs 380V/415V 50/60Hz. As regards to your Industrial RO Desalination Machine design, we will check your electrical supply and decide fix power to you.

 

Membrane Sizes and Numbers for SWRO Water Treatment Plant

Model Number

Permeate Flow Rate

 Membranes

Liter/Hour

Size

Quantity

CK-RO-2000L

2000

8040

3

CK-RO-3000L

3000

8040

3-4

CK-RO-4000L

4000

8040

4-6

CK-RO-5000L

5000

8040

5-6

CK-RO-6000L

6000

8040

8

CK-RO-8000L

8000

8040

10-12

CK-RO-10000L

10000

8040

12-15

CK-RO-15000L

15000

8040

20

CK-RO-20000L

20000

8040

28

CK-RO-30000L

30000

8040

40-45

CK-RO-45000L

45000

8040

50-60

CK-RO-100000L

100000

8040

120-150

CK-RO-200000L

200000

8040

240-300


What is a desalination system?

Some water source like seawater or some underground water or some river has high level salt inside. For high level salt water has over 10000ppm salt inside. Our Industrial RO Seawater Desalination Plant remove this salt from raw water by RO (reverse osmosis) membrane system technology. Because SW RO type membranes salt recovery rate is over 99%. So, you can get accessible, usable or drinkable fresh water. Reverse Osmosis Seawater Purification system most convenient technology to remove salt.

 

Features of Reverse Osmosis Seawater Purification Plant

Standard Futers

Available Options

Programmable PLC Control

Automatic Flush 

Motor Starter 

Ozone Generator

Raw Water Feeding/Booster Pump

UV Sterilizer

Heavy Duty Cartridge Filter Housing

Chemical Dosing

FRP Membrane Housing

pH Control Monitor

Mitsubishi Processor Control

ORP Control Monitor

Low Pressure Switch

Remote Control

High Pressure Switch

Pretreatment System

Liquid Filled Pressure Gauge

Post Deionization Unit

Coated Carbon Steel Frame

CIP Membrane cleaning System

Permeate Conductivity Monitor

Touch Screen Control

Raw Water Conductivity Monitor

Tank Level Switch

Seawater SWRO Membranes

Customer Logo

Control Valves

Special Seawater Filter

Stainless Steel/UPVC Piping

/


Operation Specification for Industrial RO Seawater Desalination Plant

Feed Water TDS  10,000 to 42,000ppm

Operating Pressure 48bar to 80bar

Over 50,000ppm Customization Required

Max. Feed Water Temp: 42°C

Operate at Higher TDS Results Lower Recovery

H2S Must Be Removed

pH Tolerance: 3-11

Max. Iron Content: 0.05ppm

Must Have Antiscalant Dosing

Feed Water Pressure: 2.5 to 6 bar

Turbidity Must Be Removed



Industrial RO Desalination Machine system price is higher than normal fresh water type RO water treatment plant. Because Industrial RO Desalination Machine uses special high pressure pump and this pumps are bigger than low TDS water treatment system’s pumps if you compare for same capacity.


FAQ
Are you manufacturer or trading company ?
Yes, we are manufacturer. Our factory is in Guangzhou Baiyun and it is very near to Baiyun airport. When you come to China, you can visit our factory....more
Get the latest price? We'll respond as soon as possible(within 12 hours)

Privacy policy

close left right